Hello, I have a 5 Series power strip it to the following can be connected: Washing Machine Dryer Semi-high freezer So lead to this 5 Series power strip is a NYY J 5x2, 5 So as underground cables quasi but this is in the concrete of the ceiling and at its destination nor the 2, 5 meters unrendered air .... Overall, wfl about 6 feet long the whole cable. As you wrdet the anschlieen? A 16 A Machine ... all 5 doses of it ... Ready? Many Supplement Gre ... washing machine about 2500 watts freezer approx 500 watts dryer about 2500 watts Is this a bit much for a cable ... If all this is operated jointly eh?
So you can make the whole cable energized wfl with a handle, I take a dignity of 3 machines to hedge, as ABB S203-C16. __________________ Gru, Thilo complete renovation bungalow BJ 71 EIBPC, Z38 (i), Elsner Suntracer Basic 24 and SO250 basic, Gira 103800, ABB 8.16.5S, 8.16.6.1, UD / S 2.300.2, Thebes HMT 12, Merten 649 315 , ETS4, Velux KLF 050, Vitogate to Vitoladens 300W/Vitotronic 200 (HO1) / KM Bus / Vitosolic 200, Siemens wfl N141/02 DALI Gateway, wfl MDT AMI 1216.01
Hello, I have a 5 Series power strip it to the following can be connected: wfl Washing Machine wfl Dryer Semi-high freezer So lead to this 5 Series power strip is a NYY J 5x2, 5 Hi, let the 5 power strip off and assembled 3 individual sockets, depending on a phase in the fuse box . When leaving a 3-pole machine 3B16. So there is no problem with the overloading of the power strip. The neutral conductor is not overloaded. If 2.5 mm is sufficient at a neutral point displacement with oblique load. __________________ Many Gre from Heuchling Kopper
I have now spoken about it with a few people ... From this 3 compartment security in 3x 2.5 I have all discouraged because of the overload n ever discussed! What is nu right? Some Balances no problem wfl .... Some say that the storms in the north adding ... The next tell about what of capacitive loads ....
I have now spoken about it with a few people wfl ... From this 3 compartment security in 3x 2.5 I have all discouraged because of the overload n ever discussed! What is nu right? Some Balances no problem .... Some say that the storms in the north adding ... The next tell about what of capacitive loads .... All true and possible. Only unfortunately is not always true everything. For example, if 3 identical loads are connected to the same power Fliet in N no electricity. With only two consumers but Fliet not automatically twice the current 2 because consumers wfl are present. For a phase shift of 120 you can easily keep track of this. With capacitive or inductive loads, the angle shifts course of 120, but not to then get 60 twice the current in the N. Therefore, for me no problem with a 2.5 mm, current carrying capacity for laying B or C in ungnstigsten case 20A. __________________ Many Gre from Heuchling Kopper
Good morning .. Something is again assumed, which is not necessarily the case ... The one speaks of phase shift, the other from OVERLOAD ... It was not mentioned that the 5x2, 5 clamped at different phases was! Apparently there are also households that have a Wechselstromzhler with only a phase ... So at various wfl phases, there will be no problem. I put dignity and individual doses at Pollin there are surface mount boxes and single connecting webs, so you can also build a fnfer combination that is wired separately. Addendum: The loads are well known, it sint Resistive Heizstbe in dryer and washing machine. The compressor and the Motrchen should be vernachlssigen as a load. Gru Jrgen
Joined: 02/01/2011 Location: St. Mary Beitrge: 154
And if de dryer is a dryer Wmepumpen? Is there ne resistive load? Anyway ... I'll pull another 2 3x2, 5 and finished wfl ... Ifs works this is the best solution. Good luck __________________ Many Gre from Heuchling Kopper
You may not be allowed to post new topics. You may not post replies to Beitrge. The time now is allowed to upload Anhnge. It is not lawful for you to edit your Beitrge. BB code is On. Smilies are On. [IMG] code is On. HTML code is Off. Trackbacks are On Pingbacks are On Refbacks are On Forum Rules Similar Threads Thread Thread Starter Forum Replies Last Post analog sensor and pressure transmitter as anschlieen? hasyfra KNX EIB Forum 5 17/06/2012 09:26 [DALI] Dali transformer properly anschlieen AlexOOOO KNX EIB Forum 2 06.01.2012 wfl 12:56 [HS / FS] - - search logic example for washing machine EinfachInButter KNX EIB Forum 7 17.11.2011 12:36 [KNX / EIB] washing machine + dryer to EIB -> Help MeierA KNX EIB Forum 4 03/06/2011 07:50 [KNX / EIB] NSLU2 to EIB KNX EIB Forum anschlieen hms 2 23